three_images

Discharger the pleural area

Gohar Shafa Chest tubes has been designed and produced in cone shape in distal end so there is no need to use a connector to connect the tubes to chest bottle or any other means.

Available in flexible types (Blue X-ray line) suitable for heart operations.
  • With high tech production line, this product has 2 different sizes in each end Which eliminate the need of using extra connector to connect to chest drainage unit (CDU).
  • Made of medical grade PVC with radiopaque line for X-ray verification of position.
  • Designed and produced in conical shape for ease of discharging of secretions.
  • All the edges are smooth to prevent any damages to the tissues.
  • This product is graduated along the first 26 Cm after the last hole, and has 6 oval shape punched holes and has 6 oval shape punched holes.
  • Available in flexible and rigid types suitable for heart and lung operations.
  • Available in infant and adult sizes.
  • Order Code Description Size (Fr.) Length(Cm) Box Master Box Latex
    CHT12R Rigid Chest Tube 12 52 100 400 NO
    CHT14R Rigid Chest Tube 14 52 100 400 NO
    CHT16R Rigid Chest Tube 16 52 100 400 NO
    CHT18R Rigid Chest Tube 18 52 100 400 NO
    CHT20R Rigid Chest Tube 20 50 100 400 NO
    CHT22R Rigid Chest Tube 20 52 100 400 NO
    CHT24R Rigid Chest Tube 24 52 100 400 NO
    CHT28R Rigid Chest Tube 28 52 100 400 NO
    CHT32R Rigid Chest Tube 32 52 100 400 NO
    CHT36R Rigid Chest Tube 36 52 100 400 NO
    CHT40R Rigid Chest Tube 40 52 100 400 NO

  • Before the patient's skin is prepared for chest tube insertion, set up the CDU according to the manufacturer's instructions.
  • Patient positioning depends on the site of the air or fluid to be drained and the patient's clinical status.
  • The practitioner cleans the patient's skin with providence-iodine or another antiseptic solution, drapes the area, and anesthetizes the skin.
  • inserting the chest tube Through a small skin incision.
  • connects its distal end to the chest drainage unit (CDU).

  • NOTE:

    These Instructions for Use are provided for informational purposes only and are not intended to take the place of product labeling. Knowledge of physician specialists with comprehensive knowledge of the indications, techniques and risks of the procedure is preferential to this instruction for use. This product contains NO natural rubber latex.


    WARNINGS:

    For single and transient use only. DO NOT REUSE, REPROCESS OR RESTERILIZE. Reuse, reprocessing or resterilization may compromise the structural integrity of the device and/or lead to device failure which in turn may result in patient injury, illness or death. Reuse, reprocessing or resterilization may also create a risk of contamination of the device and/or cause patient infection or cross-infection, including, but not limited to, the transmission of infectious disease(s) from one patient to another. Contamination of the device may lead to injury, illness or death of the patient.

    IFU code: CHT-V0-D(12/10)